Power flat cable VVGng-LS-P 0.66 kV

kabel-vvg-ngd-ploskij

Description:

VVGng-LS-P – power cable with copper conductors, PVC-compound insulation, PVC-compound outer sheath, flat, low fire hazard, without smoke and gas emission.

    Required cable section

    Number in meters

    These cable products are very popular, especially when installing electrical wiring in an apartment and a private house. The reason for the high demand for this brand is the optimal ratio of price and quality. Indeed, it is relatively inexpensive, but at the same time it has excellent parameters. The most popular cable section sizes VVG ng ls flat 2×1.5, 2×2.5, 2×4, 2×6, 2×10, 2×16, 3×1.5, 3×2.5, 3×4, 3×6, 3×10, 3×16.

    Construction:

    Conductive copper conductor, single-wire round (“ok”) or multi-wire round (“mk”), 1 or 2 classes of flexibility. For four-core cables, cores with a cross-section of 70-240 mm2 can be sector-shaped (“ms”)
    Insulation – PVC compound. Core insulation marking is color (solid or stripe) or digital. Cables are produced with blue zero conductor. Insulated conductors of multicore cables are twisted into a core. Sheath – PVC compound.

    Deciphering VVGng-ls-P:

    the absence of the letter A means that the conductor is copper
    V – PVC insulation
    V – PVC sheath
    g – (naked) lack of protective cover
    ng – does not spread combustion in group laying
    ls – (lowe smoke)are characterized by low smoke and gas emission
    P – flat, the cores are located in the same plane parallel to each other

    Cable characteristics:

    Permissible heating temperature at:
    – overload +90 degrees;
    – normal mode +70 degrees;
    – short circuit while maintaining functionality +160 +250 degrees.
    Permissible bending is limited:
    — single core cable, smallest bending radius equal to 10 times the radius of the cable;
    — multicore cable, smallest bending radius equal to 7.5 times the radius of the cable.
    The operating temperature regime is within the range of -50 +50 degrees. In the case of external cable routing, UV protection is required.
    Cable laying conditions: up to -15 degrees. In case of lower temperatures, cable heating is required.


    The use of cable:

    As for the field of application, VVGng-LS flat can be used for laying, in dry and damp industrial premises, on ramps, in mines, collectors, blocks, as well as for laying in the open air. Designed for transmission and distribution of electrical energy in stationary installations for alternating voltage 0.3 / 0.5 kV or 0.6 / 1 kV with a frequency of 50 Hz. For rated voltage 0.3 / 0.5 kV it can be used for electrical systems 0.38 / 0.66 kV.

    The scope of use of the VVG type cable is limited only to laying in the ground. Due to the absence of an armored layer, it is not allowed to lay this conductor in a trench without additional protection (for example, pipes). In this case, it is better to use armored cable VBbShv or its analogs made of aluminum.

    In the field of domestic needs, VVG is used for laying wiring in walls, cable channels and even on the street (it is recommended to protect it with a corrugation). If you need to use this cable for laying electrical wiring in a wooden house, then on wooden structures it must be laid in a metal hose, corrugation or a non-combustible cable duct. In fact, it is an ideal cable for use as electrical wiring in an apartment or a private house, connecting to sockets, lighting, etc.

    The price of the VVG cable depends on the section. As for the sections, for the lighting group, 3×1.5 is optimal, for 3×2.5 sockets, and for connecting a stove, boiler or other powerful household appliances 3×4, which can withstand power up to 8 kW.