Каталог
Меню

Central office:

Phone: (061) 220-15-00 / (098) 441-15-41

Email: Office@mpka.com.ua

Branch Kyiv:

Phone: (044) 227-36-77 / (068) 774-74-77

Email: Kiev@mpka.com.ua

Branch Lviv :

Phone: (067 ) 612-38-37 / (067) 678-93-24

Email: rm.east@mpka.com.ua

Cable power armored AVEVBbShv 6 kV

visokovoltniy_alyuminievij_kabel_avevbbshv

Description:
AVEVBbShv cable is a high-voltage armored power cable with aluminum conductors, with PVC insulation in a PVC sheath, for a rated voltage of 6000 volts. Mainly used in underground workings of mines for horizontal, inclined and vertical laying.

    Required cable section

    Number in meters

    Design:
    Conductive conductors – Aluminum stranded twisted round or sector (class 2 according to DSTU).
    Insulation – Polyvinylchloride compound.
    Screen over insulation – Copper tape.
    Grounding conductor – Round copper stranded, twisted without insulation or split, consisting of several wires (class 2 according to DSTU).
    Belt insulation over the twisted core – Polyvinylchloride compound.
    Protective cover type BbShv – Armor made of two steel tapes (BbShv), protective hose made of polyvinylchloride compound.

    Cable decryption:
    A – cable cores are made of aluminum
    V – Insulation of polyvinyl chloride plastic
    E – Individual screen of veins
    V – Shell made of polyvinyl chloride plastic
    B – Armor of two steel tapes
    b – Without a pillow
    Shv – Protective hose from polyvinylchloride plastic

    Application area:
    AVEVBbShv-6 kV cable is designed for transmission and distribution of electrical energy in stationary networks for a rated voltage of 6 kV at a frequency of 50 Hz at an ambient temperature of minus 30 °C to plus 50 °C and a relative humidity of 98% at a temperature of plus 35 °C, when laying them along horizontal and inclined workings of mines and along wells suspended from a cable and vertical workings of mines that are not hazardous in terms of gas and dust when laid alone and when laid in bundles. Laying and operation – in the ground (in trenches) with low corrosive activity, where protection against mechanical damage is required without significant tensile forces.

    Tabular data:

    Nominal cross section, mm2 Permissible current loads, amperes (A)
    in the air in the ground
    25 85 90
    35 105 110
    50 125 130
    70 155 160
    95 190 195
    120 220 220
    150 250 250
    185 290 285
    240 345 335

     

    Additional parameters:

    Number of cores and nominal cross section, mm2 Rated voltage, kV Outer diameter of the cable, mm Estimated weight of 1 km of cable, kg
    3х25 6,0 37,3 2082
    3х35 6,0 39,7 2358
    3х50 6,0 42,6 2694
    3х70 (sector) 6,0 43,3 2676
    3х95 (sector) 6,0 46,8 3140
    3х120 (sector) 6,0 50,0 3544
    3х150 (sector) 6,0 53,1 4086
    3х185 (sector) 6,0 56,7 4653
    3х240 (sector) 6,0 61,0 5391
    3х25+1х10 6,0 37,3 2104
    3х35+1х16 6,0 39,7 2414
    3х50+1х16 6,0 42,6 2749
    3х70+1х25 (sector) 6,0 43,3 2810
    3х95+1х35 (sector) 6,0 46,8 3349
    3х120+1х35 (sector) 6,0 50,0 3752
    3х150+1х50 (sector) 6,0 53,1 4399
    3х185+1х50 (sector) 6,0 56,7 4966
    3х240+1х50 (sector) 6,0 61,0 5704

     

      Fill out the form

        Send a request for a miscalculation

          FILL IN THE FORM